If you are an experienced electrician researching how to get an electrician Gold Card without having completed the traditional apprenticeship route, the City & Guilds 2346-03 Level 3 Electrotechnical Experienced Worker Qualification allows you to demonstrate the competence you have already developed through work. A major part of that process is providing evidence against specific performance requirements. This evidence is reviewed by a qualified assessor, who checks your work against the tasks and standards set out in the qualification.


The qualification has five mandatory performance units, plus a specialist unit for either the Installation or Maintenance pathway. For each, you’ll need evidence from two separate occasions, so the important starting point is understanding exactly what each one requires you to demonstrate.

1. Apply Health, Safety And Environmental Considerations

This unit covers how you apply health and safety requirements during electrical work: producing and following risk assessments and method statements, identifying and controlling hazards, selecting PPE, using tools and access equipment safely, and following environmental requirements for materials and waste.

This is one area where photographs and written accounts alone are not sufficient. A qualified assessor must directly observe you in the workplace on two occasions, and at least one must be a face-to-face site visit; the second may be completed by live-streamed assessment. 

2. Organise And Oversee The Electrical Work Environment

Here you are demonstrating that you can organise collaborative electrical work rather than simply carry out your own task. Depending on the work, evidence could include programmes or schedules, risk assessments and method statements, job records, resource or materials documentation and witness evidence confirming how you coordinated or supervised the work.

3. Termination And Connection Of Conductors

This unit requires you to demonstrate safe preparation followed by competent termination and connection. The required range includes five types of cable or conductor, connections to five types of electrical equipment and at least two termination methods, as well as ensuring connections are mechanically and electrically sound and correctly identified.

Your portfolio can use authenticated photographs and workplace records to establish the range of work completed, but for learners registered from 1st May 2026, the actual termination and connection work in Learning Outcome 2 is also subject to direct assessor observation.

4. Apply Design And Installation Practices And Procedures — Installation Pathway

If you are taking the Installation pathway, this unit demonstrates your ability to prepare for and carry out electrical installation work from the information provided, before confirming the completed work meets the specification and BS 7671.

Useful evidence can include the drawings or specification you worked from, job documentation and authenticated photographs and videos showing work during installation and on completion. This unit is also included in the new expanded direct-observation requirements.

5. Apply Practices And Procedures For Maintenance — Maintenance Pathway

If you are following the Maintenance pathway instead, you’ll need to demonstrate how you plan, carry out and record maintenance. Evidence might include maintenance schedules and specifications, permits to work, method statements, servicing records, job sheets, test results and completed maintenance records. The criteria also requires you to evaluate the effectiveness of the work and make recommendations where appropriate.

6. Inspect, Test And Commission Electrical Systems

This unit covers the complete process from making the installation safe through visual inspection, testing, certification and handover. Your evidence will need to demonstrate appropriate safe isolation, how you select and use the correct instruments, interpret the results and complete the relevant certification. Tests include continuity, insulation resistance, polarity, earth fault loop impedance or earth electrode testing, prospective fault current, RCD operation and functional testing. This unit is also subject to the expanded direct-observation requirement.

7. Apply Fault Diagnosis And Rectification

Finally, you must demonstrate that you can investigate a fault logically, identify its cause, carry out an appropriate repair and verify that the system or equipment is operating correctly afterwards. Strong evidence could therefore combine the original job or fault record, relevant drawings, recorded test results, evidence of the corrective work and the final inspection or test results confirming the repair. What the assessor needs to see is the complete chain from identifying the problem through diagnosis and rectification to confirming the final result.

How To Get An Electrician Gold Card? Find Out More

You’ve already put the years in on the job. Talk to PTT today about using your workplace experience and evidence to progress towards your Level 3 qualification and electrician Gold Card.